Pulse length |
20ns f.w.h.m. |
Trigger
Input |
3 volts 10ns f.w.h.m. into
50Ω |
Maximum repetition rate |
Depends upon the voltage.
40Hz at 15kV into an open circuit. |
Voltage
range |
-0.2kV to -15kV as a negative
pulse device |
Jitter |
Approximately 100ps or less
(hard to measure) |
Main
output |
Output will > 20kV
into an open circuit with the HT set to maximum.
Output will drive and resistive or slightly capacitive (<1nF)
load at the end of a 75Ω
cable. |
Synchronisation
Output |
TTL approximately 50ns after
trigger.
Reverse terminated 75Ω |
Remote
HT enable |
This 12 volt input needs to
be shorted to activate the HT |
Status |
TTL (high on ready) on the
front panel for remote interrogation of the status. The status
is high when the voltage on the switch equals that preset on
the front panel, and when the HT is on. |
Connectors
|
|
Power |
IEC Universal 85 to 264 volts
A.C. at 47 to 440Hz. 2 amp fuse, type T (anti-surge). This unit
contains an auto-resetting thermal trip rated at 70°C. Maximum
average power consumption 25 watts. |
Trigger
input |
BNC |
Sychronisation
output |
BNC |
Status
Output |
Lemo 00 (Part number FFA.00S.250.CTA
C27) |
HT
Enable |
Lemo 00 (Part number FFA.00S.250.CTA
C27) |
Main
output |
Fischer DK105A005/7.2 Note
that the output has a female centre pin. |